Banner Images

WHAT'S NEW

Reliable Controls

NCH is now a Reliable Controls Authorized Dealer

TIP...
of the Iceberg

Date stamp your furnace filter

Monitor your filter changes more effectively by dating the filter whenever you replace it

Our PROJECTS

Commercial Rooftop Unit

Lennox Commecial Rooftop Unit

Commercial Rooftop Unit

Frequently Asked QUESTIONS

FAQ

Can I use an existing well for my Geo loop?

The use of an existing well is a possibility but generally not conducive to a proper closed loop installation. The depth of the well and size of casing will be a consideration. Vertical loops are generally drilled by way of a 3' casing to a depth determined by the loop requirement. The well is then filled with a slurry to optimize heat transfer. The number of wells required is calculated as per the heating / cooling load of the home

read details

I am not getting enough water pressure from my Well

Well water pressure can be indicative of a number of issues but a simple check is to ensure your pressure tank is properly charged. The tank pressure should be 2PSI below your pump cut-in pressure setting. For example, if your pump cuts in at 30PSI, your tank should be charged at 28PSI, if it cuts in at 40PSI then it should be set at 38PSI. The pump cut-in pressure can be determined by running your water and watching your gauge (hence the importance of a good quality gauge). It should cut in and out in 20PSI intervals.